Long-Term Moisture Absorption in Graphite/Epoxy Angle-Ply Laminates
Mårten Blikstad
Linköping Institute of Technology Department of Mechanical Engineering S-581 83 Linköping, Sweden
Peter O.W. Sjöblom
Linköping Institute of Technology Department of Mechanical Engineering S-581 83 Linköping, Sweden
Thomas R. Johannesson
Linköping Institute of Technology Department of Mechanical Engineering S-581 83 Linköping, Sweden
Angle-ply laminates of graphite/epoxy Fiberite T300/1034, Ciba-Geigy T300/920 and Ciba-Geigy T300/914 were exposed to moist air of different relative humidities for 400 days. Laminates of T300/1034 reach a first plateau after about 100 days and a se cond plateau of saturation after about 400 days. The plateau levels are functions of the relative humidity and also of the residual stresses in the laminate. Compressive residual stresses retard the diffusion and lower the plateau levels. Laminates of T300/920 and T300/914 show more rapid moisture absorption than laminates of T300/1034 but no clearly detectable saturation plateau. The shoulder of the moisture content vs. square root of time curve is over-estimated by the one-dimensional solution of Fick's equation of moisture diffusion. A three-dimensional solution is given and is shown to predict the moisture absorption better for specimens of small width to thickness ratio.
Journal of Composite Materials, Vol. 18, No. 1,
32-46 (1984)
DOI: 10.1177/002199838401800103

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
D. A. Bond
Moisture Diffusion in a Fiber-reinforced Composite: Part I - Non-Fickian Transport and the Effect of Fiber Spatial Distribution
Journal of Composite Materials,
December 1, 2005;
39(23):
2113 - 2141.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Srihari and R. M. V. G. K. Rao
Hygrothermal Characterization and Diffusion Studies on Carbon/Epoxy Composites
Journal of Reinforced Plastics and Composites,
July 1, 1999;
18(10):
921 - 930.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Srihari and R. M. V. G. K. Rao
Hygrothermal Characterisation and Diffusion Studies on Glass Epoxy Composites
Journal of Reinforced Plastics and Composites,
July 1, 1999;
18(10):
942 - 953.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
L. C. Bank, T. R. Gentry, and A. Barkatt
Accelerated Test Methods to Determine the Long-Term Behavior of FRP Composite Structures: Environmental Effects
Journal of Reinforced Plastics and Composites,
June 1, 1995;
14(6):
559 - 587.
[Abstract]
|
 |
|

|
 |

|
 |
 
P.C. Upadhyay and A. Mishra
Modified One-Dimensional Fickean Solution for Moisture Absorption in Composites
Journal of Reinforced Plastics and Composites,
July 1, 1990;
9(4):
335 - 345.
[Abstract]
|
 |
|

|
 |

|
 |
 
H. Bouadi and C.T. Sun
Hygrothermal Effects on the Stress Field of Laminated Composites
Journal of Reinforced Plastics and Composites,
January 1, 1989;
8(1):
40 - 54.
[Abstract]
|
 |
|

|
 |

|
 |
 
M. Blikstad
Three-Dimensional Moisture Diffusion in Graphite/Epoxy Laminates
Journal of Reinforced Plastics and Composites,
January 1, 1986;
5(1):
9 - 18.
[Abstract]
|
 |
|
|
|