Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Journal of Composite Materials
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Romeo, G.
Right arrow Articles by Frulla, G.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Analytical and Experimental Results of the Coefficient of Thermal Expansion of High-Modulus Graphite-Epoxy Materials

Giuuo Romeo

Politecnico di Torino, Department of Aerospace Engineering, C.so Duca Degli Abruzzi 24, 10129 Turin, Italy

Giacomo Frulla

Politecnico di Torino, Department of Aerospace Engineering, C.so Duca Degli Abruzzi 24, 10129 Turin, Italy

The coefficient of thermal expansion (CrE) of an arbitrary laminate can be determined by the Classical Laminate Theory. However, the results obtained have shown that the CFE is very sensitive to some orthotropic elastic constants and to the laminate layup. In particular, the non-Hookean behaviour of an unidirectional lamina in the fibres direction should have to be taken into account to exactly predict the CTE.

In order to verify the theoretical analysis, a new test facility has been designed to carefully measure the CTE in specimens made of advanced composite materials having a quasi zero value of CTE. The facility is basically composed of two thermostats and contained in a vacuum chamber (10–2 Pa). Four specimens are enclosed in the first thermostat and the operating temperature range is limited to –20°C up to 80°C. Four displacement transducers are enclosed in the second one at a temperature of 20°C and kept rigorously constant within 0.1°C. The specimens are mounted on Ultra Low Expansion (ULE) frames having a CTE of 1 x 10–8/°C. It has been possible to miniize the measurement error in the CTE, by a careful choice of displacement sensors and the high control of their thermal stability.

The following CTEs have been obtained along the fibre direction, normal to the fibre direction and for a quasi-isotropic laminate, respectively, for two High-Modulus (HM) graphite/epoxy materials.

GY70/M18: {alpha}1 = –1.04 x 10–6/°C; {alpha}2 = 33.9 x 10–6/°C; {alpha}x = -0.095 x 10–6/C

M55J/M18: {alpha}1 = –1.02 x 10–6/°C; {alpha}2 = 35.2 x 10–6/°C; {alpha}x = –0.162 x 10–6/°C

The analytical results have shown as a variation of ±1° only in the lamina orientation can change the CTE of the quasi-isotropic laminate up to ±50.5% of the theoretical value; as well as, a variation of ±5% in the physical and mechanical properties can change the CTE up to ±48%.

Key Words: coefficient of thermal expansion • high dimensional stability laminate

Journal of Composite Materials, Vol. 29, No. 6, 751-765 (1995)
DOI: 10.1177/002199839502900604